ENOFY climate · Hall heating
Warm under the roof, cold below?
Our hall heating warms people, not the air under the roof.
Electric infrared hall heating for industrial and logistics halls up to 10 m high: zone by zone, no gas, no pipes, no maintenance. Made in Germany.
Typical in halls
Sound familiar?
Four problems we hear in almost every hall, and our answer to them.

Warm under the roof, cold at the workplace.
Radiant heat like the sun: it warms people, floors and machines directly, not the air under the roof.

Gas and CO₂ costs rise every year.
100% electric, no gas: no CO₂ levy on gas. With solar power from your own roof it gets even cheaper.

Maintenance, breakdowns, chimney sweep.
Maintenance-free: no burners, no fans, no moving parts. 20-year warranty on the heating panels.

Replacing the heating brings work to a halt.
Installed by your electrician: no pipes and no boiler room. The old heating can stay during the transition.
How hall heating works
Warm air heats the roof. Radiation heats the workplace.
Warm air rises. In high halls it collects under the roof, where nobody works. Infrared hall heating warms people, floor and machines directly.
- No cushion of heat under the hall roof: no energy is wasted on hot air that nobody needs up there.
- The heat stays in the floor and the building fabric, even when a loading door is open.
- An air temperature 2 to 3 °C lower is enough for the same comfort.
- No fan: no draught, no stirred-up dust, no noise.
The heating panel
What the heating panel looks like.
Only 12 mm flat: the 2 mm heating laminate at the front, the insulation board behind it. Rotate the model with your mouse or finger.
Drag to rotate the model
- Typ
- AWH-380
- Abmessungen
- 750 × 600 × 12 mm
- Leistung
- 380 W
- Gewicht
- 4,4 kg
Dargestellt ist die Größe 750 × 600 mm. Die Größen 750 × 400, 750 × 800 und 750 × 1000 mm sind gleich aufgebaut. Schematische Darstellung: Maße, Leistung und Gewicht nach den Datenblättern; Stifte, Bohrungen, Dämmplatte und Kabelführung sind vereinfacht gezeichnet.
In practice
Hall heating in the logistics centre.
A selection of our projects. We are happy to name further references on request.
Logistics centre near Hanover: new build with 7,000 m² of hall space and a roof height of 10 m. The hall heating holds a constant 18 °C, zone by zone and 100% electric. According to the operator, the investment was around 70% below that for commercial heat pumps.




Reference values apply to the building in question and are no guarantee for other buildings.
Videos
Hall heating explained in two short videos.
Why many halls stay cold despite high heating bills, what happens when the doors are open and how zone-by-zone heating works: our CEO Friedrich Büscher answers the key questions, and a short explainer sums up the system. Both videos are in German with English subtitles.
Interview: Friedrich Büscher, CEO of ENOFY (4 min)
German with English subtitles. Created with AI · Watch on YouTube →
Explainer: why rethinking hall heating pays off now (1.5 min)
German with English subtitles · Watch on YouTube →
Quick calculator
Calculate the heat output for your hall.
Enter the dimensions and see a guide value instantly. No sign-up, no e-mail. Also for several halls with offices.
More precise calculation (optional)
Your guide value for heat output
from 42 kW
- No gas, no boiler room
- No pipes, no risk of water damage
- Maintenance-free, 20-year warranty on the heating panels
- Installed by your electrician, each module on 230 V
- One system for hall, offices and staff rooms
Cost estimate by e-mail
Your e-mail is enough – we send you a guide value and first costs within 48 hours. Add your phone number and we will gladly call you back.
Or call us directly: 0521 16393186
Guide value without guarantee, not a specialist design. We do the exact design with your details.
What does hall heating cost?
That depends on floor area, ceiling height, use, insulation and location. From these details we calculate the heat load and a guide price for your hall.
1 · At purchase
- Heating panels and electrical cabling instead of heat generator, buffer tank and pipework
- No gas connection, no flue system
- Mounted under the ceiling, no work on the hall floor
- Also for retrofitting: no heating circuit needed
- Modular: you buy only the output your hall needs
2 · In operation
- No maintenance: no burner, no pump, no moving parts
- Heating only in the zones and at the times in use
- Air temperature 2 to 3 °C lower for the same comfort
- No CO₂ price on fuel, no fuel quota
- Your own solar power turns directly into heat
Funding and financing: we calculate ENOFY hall heating without subsidies. For energy management there is a German federal grant (BAFA, Module 3). Purchase, financing through partners or contracting: we clarify this with your quote.
How your project works.
Four steps to a warm hall.
Enquire
Questionnaire or phone call: you tell us the floor area, ceiling height, use and insulation of the hall.
Design
We design the layout of the heating panels as closely as possible in line with the DIN standards. We state our assumptions openly.
Quote
You receive heating panels, controls and prices in clear figures.
Install
The installation is carried out by a qualified electrical contractor. We deliver and support you with any questions.
For planners and engineering firms: Heat load available? Send us the heat load and hall dimensions. Within 48 hours you receive a budget, data sheets for your planning and delivery in step with your construction schedule. We plan and deliver across Germany. Send your project →
Good to know: our design does not replace specialist planning. Detailed specialist planning with U-values and heat load must be prepared by an energy consultant. Installation is carried out by a qualified electrical contractor commissioned by you.
Frequently asked questions about hall heating.
Which hall heating is suitable for high halls?
Radiant heating is suitable for high halls: it warms people and surfaces directly, not the air under the roof. ENOFY hall heating is an electric infrared heating system and warms from a height of 4 to 10 metres.
What is industrial hall heating?
Industrial hall heating heats production halls, warehouses and logistics halls. Because warm air in high halls rises under the roof, radiant heating is the right fit: it warms people and surfaces directly. ENOFY infrared heating is an electric industrial hall heating system for heights of 4 to 10 metres.
Can a hall be heated electrically?
Yes. The electric ENOFY hall heating heats with infrared, 100% electric, with no gas, no pipes and no central heating plant. One example is a logistics centre near Hanover with 7,000 m² and a roof height of 10 m that is kept at a constant 18 °C.
What does hall heating cost?
That depends on floor area, ceiling height, use, insulation and location. From these details ENOFY calculates the heat load and a guide price. For the logistics hall near Hanover, the investment was, according to the customer, around 70% below that for commercial heat pumps.
What is the difference from radiant tube heaters and luminous heaters?
Radiant tube heaters and luminous heaters burn gas and operate at several hundred degrees. They need a gas connection, a flue system and regular maintenance. ENOFY hall heating works electrically with up to 120 °C at the surface, with no flue gases and no maintenance. For very high halls above 10 metres, gas radiant heaters remain an option.
Hall heating with infrared or with a heat pump?
Both heat without gas, but in very different ways. A heat pump warms water or air and needs an outdoor unit, buffer tank, pipework and heat emitters in the hall. Infrared hall heating needs only heating panels and electrical cabling, warms people and surfaces directly and heats only the zones in use. Which system fits depends on hall height, hours of use and the equipment already in place.
Is infrared hall heating more expensive than a heat pump?
Not to buy: it costs significantly less, with no outdoor unit, no buffer tank, no pipework and no fan heaters. In operation it cannot be compared per kilowatt-hour. A heat pump’s seasonal performance factor applies to systems that heat the air, and in a hall warm air rises to the roof. Infrared hall heating warms people, floors and machines directly, only in the zones in use, and is warm within minutes. It therefore needs far less heat overall. In high halls with zoned operation, our experience is that electricity costs are on the same level as a heat pump.
Can the hall heating be retrofitted in an existing hall?
Yes. The heating panels are mounted under the ceiling and connected to the power supply. No work on the hall floor or heating circuit is needed. The electrical installation is carried out by a qualified electrical contractor.
How is the hall heating controlled?
Each zone gets a thermostat that switches the heating panels on and off via a switching unit. In industrial halls the zones can be integrated into the energy management system.
What does Germany’s Building Modernisation Act mean for hall heating?
Germany’s Building Modernisation Act (Gebäudemodernisierungsgesetz) has been in force since July 2026. Which requirements apply to your hall depends on the building and its use. ENOFY hall heating heats without fuel: no CO₂ price on gas or oil is incurred. We check the requirements for your project.
Is there funding for hall heating?
We calculate ENOFY hall heating without subsidies. Its advantage is the low investment. For energy management in companies there is a German federal grant (BAFA, Module 3): 45% for small, 35% for medium-sized and 25% for large companies. There is no legal entitlement.
Where does ENOFY operate?
ENOFY is based in Bielefeld, Germany. Its focus is on East Westphalia-Lippe and North Rhine-Westphalia. ENOFY plans and supplies hall heating throughout Germany.
What information do you need for a quote?
Floor area, ceiling height, use, insulation and location of the hall, plus the work zones and the electrical connection. We are happy to send you the questionnaire for industry and commerce.
How much heat output does my hall need?
As a guide value we calculate per square metre of heated area: newer halls 30 to 70 W/m², older halls 65 to 140 W/m², workshops 25 to 65 W/m². The better the insulation, the lower the value. Example: a newer 1,000 m² hall with good insulation needs about 40 W/m², i.e. around 40 kW. With a 10% reserve that is about 22 modules of 2,000 W each. If only the work zones are heated, the output drops accordingly. We calculate the exact heat load from your details.
What does it cost to run hall heating on electricity?
One kilowatt hour of electricity becomes one kilowatt hour of heat. The costs depend on output, heating hours and your electricity price. Example: ten modules of 2,000 W each have 20 kW in total. Running for one hour at full output, that is 20 kWh, so €5 at €0.25 per kWh. In operation the thermostat controls the panels, and heating only runs in zones and at times that are in use. Your own solar power cuts the costs further.
Hall heating with warm air or with radiation?
In high halls warm air rises: it is warm under the roof, the workplace stays cool, and when the doors open the warm air is lost. Radiation warms people, floors and racks directly. As a result, an air temperature 2 to 3 °C lower gives the same comfort.
Are there electric infrared hall heaters without gas?
Yes. The ENOFY hall heating works like a hall heater under the ceiling, but electrically: no gas connection, no flue gas and no maintenance, with up to 120 °C at the panel surface. It warms people and surfaces directly and can be switched by zone.
Can the hall heating keep a hall frost-free?
Each zone can be set to a low target temperature, for example 5 °C for frost protection in machine, vehicle or storage halls. Whether radiant heat is the right solution for your frost protection depends on the hall, insulation and use. We check this with your data.
I am a planner: do I get a design and a budget for my cost estimate?
Yes. We give a first cost estimate within 48 hours once enough information is available. Helpful are a short conversation or call, details on the hall and its use (heat load, dimensions, insulation, target temperature, use) and photos of the hall. We prepare an outline design with the number and output of the modules and name a budget. Data sheets and technical details for your planning are included.
Is the ENOFY infrared hall heating made in Germany?
Yes. The electric infrared hall heating from ENOFY is made in Germany. We agree the delivery time with you depending on quantity and time it to your construction schedule. Prices remain stable even for large projects. The heating panel was tested by the Karlsruhe Institute of Technology (KIT), and every panel comes with a 20-year warranty.
How long is the delivery time, also for large projects?
The ENOFY hall heating is made in Germany. We agree the delivery time with you depending on quantity. We time deliveries to your construction schedule and deliver directly to the site.
Are prices stable even for large quantities?
Yes. Because we manufacture in Germany, prices remain stable even for large projects. Discounts are possible for larger quantities. We give you a budget with the first cost estimate within 48 hours.
Which halls can be heated with the ENOFY hall heating?
Storage, production, logistics and vehicle halls as well as workshops up to 10 m high. The infrared panels warm the places where people work. The air under the roof does not need to be heated too, and when the doors open the heat stays in people and surfaces.
Can I heat only certain areas of the hall?
Yes. The hall is divided into zones, each with its own thermostat. Heating only runs where people work, for example at workstations, order picking or loading. A zone reaches full output in under 5 minutes; empty zones stay off.
What power connection does the hall heating need?
Each heating module runs on the normal 230-volt grid and is connected by your electrician, without a heating engineer and without pipes. We calculate how much power the whole hall needs and check during planning whether your existing connection can carry it.
Can the hall heating also heat offices and staff rooms?
Yes. The same technology is available as an insert for suspended ceilings (612 × 612 mm) and as a module for walls and ceilings. Hall, offices, staff areas and foyer are heated with one system, so you do not need a second heating system.
Can the hall heating be combined with solar and storage?
Yes. The hall heating turns electricity directly into heat. If the power comes from your own hall roof, the hall is heated with solar power, and a battery takes over in the evening and at night. On request we plan the solar system, storage and energy management with you.